Thursday, June 17, 2010

New from JH Technology

FAST Response!

Transmitters with 1 millisecond response time.

Last year we spotlighted a new design we'd done for a customer needing a quantity of fast-response transmitters. We've now turned it into a standard product offering.



Available on most of our DIN-rail transmitters (JH5000 Series), Option HS output is approximately complete (95% response) in 0.001 seconds. It is not available on AC input or frequency input transmitters, as these require filtering to function properly.

Frequency response is 3dB down (0.707 times the DC gain) at approximately 600 Hz.

Faster (or slower) available - contact us!


Sunday, June 13, 2010

Custom Designs

A Very Special Special

A well-known company needed to duplicate a thermocouple alarm they had bought from Action Instruments decades ago. Action was no longer able to provide it so they turned to us.

Action's original "Action Pak" line (Action's trademark) once included alarm modules with extra options such as retransmitting outputs and remote setpoint inputs. 20-pin headers (pin bases) were required to provide the extra connections. As far as we are aware these headers are no longer available.

Our customer's requirement was a nonstandard version of one of those alarms. We replied that we could provide the same function but with a different connection arrangement. This was not acceptable - it was for a nuclear power application and they could not vary the system design. Only one piece, but they were willing to pay for it.

Once again we got lucky. In 1995 we had purchased some 20 pin headers for another customer's need and had a handful left. Our customer bought one (couldn't convince them to buy a spare) - even sent an inspector to Florida to do a source inspection. That was 2008. In 2009 they again bought one and just now ordered two more! Possible future problem - after this order we have only five headers left.

(Note: We do not sell nuclear-approved products. This alarm was sold as "standard commercial quality" for a noncritical application.)

Technical detail: the custom alarm module has two retransmitting 0-1V analog outputs, one proportional to temperature and the other proportional to the setpoint. Our customer was able to supply us with Action's specifications and we designed it to be functionally identical. Here's the functional diagram.



If you have special requirements let us know. Phone (941) 927-0300 or toll-free (800) 808-0300.