Some People Like
Trimpots!
We recently picked up a new customer who ordered a few of our 2-wire thermocouple transmitters. This customer sells thermocouples and other temperature probes, and the manufacturer they represent also offers transmitters from a well-knows European company.
Why did they buy ours? The European brand is computer-ranged. The end user wanted to be able to adjust calibration without needing a computer set-up. So, they bought our "old fashion analog" fixed range Model JH220 - complete with trimpots!
This is at least the second time this has happened. Another of our customers, a temperature sensor manufacturer, ran into exactly the same objection years ago and regularly offers our transmitters even though they also handle the European brand.
Do you need to change ranges but still like trimpots? Model JH225 (shown) adds switches that let you recalibrate to almost any practical range for thermocouple types J, K and T. (You do need a calibration source.) We also offer similar transmitters for RTD (resistance thermometer) sensors.
Links:
Model JH220, thermocouple 2-wire transmitter, fixed range (factory set)
Model JH225, thermocouple 2-wire transmitter, user-rangeable
Model JH240, RTD (resistance thermometer) 2-wire transmitter, fixed range
Model JH245, RTD 2-wire transmitter, user-rangeable
All 2-Wire Transmitters
Saturday, February 13, 2010
Saturday, February 6, 2010
Simple Specials
Standard Product, Nonstandard Connections
The answer was simple - take our standard product, unsolder the internal wires from the pins and rewire them to be the same as the British product. And, since the the connections to the thermocouple were changed, we also needed to relocate the temperature sensor used for cold junction compensation.
One more step - we made a simple adapter to allow the converted alarm module to plug into our standard production test and burn-in fixtures.
This customer buys only one or a few at a time, but they've become a regular for several years.
Links: Process Alarms
JH1200 Thermocouple Alarm
Custom & Special Signal Conditioners
Links: Process Alarms
JH1200 Thermocouple Alarm
Custom & Special Signal Conditioners
Thursday, February 4, 2010
Simple Specials
SPECIAL ORDER -SUM THREE UNEQUAL FLOWS
Flow #1: Full Scale (20mA) = 1.75 MGD (Million Gallons per Day)
Flow #2: Full Scale (20mA) = 22 MGD
Flow #3: Full Scale (20mA) = 1.04 MGD
Module Output: Full Scale (20mA) = 24.79 MGD
Something we do all the time - modify our products to meet out-of-the-ordinary needs. In this case the customer needed to add signals from three flowmeters, each having a different scale factor.
A bit of engineering calculation, followed by the selection of a few precisely-measured input resistors, did the trick.
One piece order. Turn-around time - four days from order entry to shipment.
Sunday, January 31, 2010
Product Spotlight
Two-Wire Transmitter - Potentiometer Input
Our "sleeper" product - not new and, you would think, not particularly exciting, but people keep finding it and buying it, so we thought we'd feature it.
Pretty simple - takes a potentiometer input and converts it to a 4-20mA two-wire (loop-powered) output. Quite honestly, it was an afterthought when we designed our temperature (RTD and thermocouple) two wire transmitters years ago. Laying out the circuit board so it could also be assembled for potentiometer input was easy, so we included it.
Sells better than we ever expected. Just this month we picked up two new customers for it. The applications can be anything that needs to convert position to an electrical signal. A couple applications - level measurement and boat throttle position. The level measurement application uses a probe with series of resistors and reed switches, activated by a magnetic float.
Labels:
2-Wire,
4-20mA,
Signal Conditioners,
Transmitters
Friday, January 8, 2010
Can You Help????
Here's a question we can't help with. Can you?
The other day a fellow called to ask if we could build a custom dashboard panel for his car. We've had two similar calls recently - at least one of them was from a man who was converting an older model to electric power. (He wanted it to look as much like the original dashboard as posssible.) All of them had seen from our web site that we can design panels and minisystems.
This is outside our area of expertise. Industrial control panels, yes. Automotive, no. We'd need to know the size, shape, mounting arrangements etc of the car's dashboard and the electronic details of the car's sensors.
I thought I'd post this for our readers. Can you help, or do you know anyone who can?
The other day a fellow called to ask if we could build a custom dashboard panel for his car. We've had two similar calls recently - at least one of them was from a man who was converting an older model to electric power. (He wanted it to look as much like the original dashboard as posssible.) All of them had seen from our web site that we can design panels and minisystems.
This is outside our area of expertise. Industrial control panels, yes. Automotive, no. We'd need to know the size, shape, mounting arrangements etc of the car's dashboard and the electronic details of the car's sensors.
I thought I'd post this for our readers. Can you help, or do you know anyone who can?
Sunday, January 3, 2010
Product Spotlight
.
Field Mount Enclosures
In our last posting (December 26,2009) we highlighted our FDT5000 Series field mount transmitters with displays. If you don't need a display you can mount any of our plug-in transmitters and alarms in the two enclosures featured here.

NEMA-4X Rated Enclosure
Splashproof & corrosion resistant, it includes the mating socket. It is normally sold without an opening or conduit connection as the installer usually prefers to determine this detail. If you would like us to provide this please e-mail jhtek@jhtechnology.com or call 941-927-0300 (in the US, toll-free 800-808-0300) us with your requirements.
Part #ENCL-1-8 with 8-pin socket, or ENCL-1-11 with 11-pin socket.
.
Explosion Proof Enclosure
This is a Hubbell-Killark enclosure, modified by adding an 8- or 11-pin socket. UL, CSA and Factory Mutual approvals include Class 1, Div 1 & 2, Groups A, B, C & D when properly installed. A neoprene o-ring assures water-resistance per NEMA 4/IP66. Two 3/4 inch-14 NPT threaded conduit openings are provided.
Part #ENCL-EX1-8 with 8-pin socket, or ENCL-EX1-11 with 11-pin socket.
Labels:
Accessories,
Enclosure,
Explosion-Proof,
Field Mount
Saturday, December 26, 2009
Product Spotlight
Field-Mount
Transmitters
with Displays
Designed for outdoor and other wet/dirty environments, our FDT5000 series transmitters feature:
- Splashproof/ Corrosion Resistant Enclosure per NEMA 4X
- User-Rangeable 3-1/2 Digit Display
- Wide Selection of Input Styles
- Voltage or Current Output Ranges
- AC and DC Power Options
If you don't need a display, we also offer NEMA 4X and explosion-proof enclosures for our plug-in transmitter and alarm modules.
Our home page: http://www.jhtechnology.com/
Labels:
Field Mount,
Signal Conditioners,
Transmitters
Subscribe to: